Specs

Basic Specs

Basic Specs

    Lidar Ports
    9
    Voltage
    10~23 V DC (Typical 12 V DC)
    Input Power ¹
    25 A @ 12 V
    Data Interface
    1Gbps Ethernet
    Operating Temperature
    -40°F to 185°F (-40℃ to 85℃)
    Time Sync Protocol
    IEEE 1588-2008 (PTPv2)
    GPS
    Weight ²
    Approx. 865 g (without port covers)
    Approx. 1352 g (with port covers)
    Dimensions ²
    153.2 × 201 × 29 mm (without port covers)
    208 × 201 × 29 mm (with port covers)
    Notes
    1. The typical input power of Livox Hub is 180 W (12 V, 15 A) when five Livox Mid-100 sensor units are connected at a temperature of 77°F (25°C) using an external power supply of 12 V. The output power of Livox Hub varies based on the number of the Livox LiDAR sensors connected and will be affected by the operational temperature. Refer to the Livox LiDAR sensors' user manual to view their working power.
    2. The port covers are detachable. Users can attach or detach the four port covers based on personal demands.