Specs

Basic Specs

Basic Specs

    Model
    Mid-40/Mid-100
    Laser Wavelength
    905 nm
    Laser Safety
    Class 1 (IEC60825-1)
    Detection Range (@ 100 klx)
    90 m @ 10% reflectivity
    130 m @ 20% reflectivity
    260 m @ 80% reflectivity
    FOV
    38.4° Circular (Mid-40)
    98.4° (Horizontal) × 38.4° (Vertical) (Mid-100)
    Range Precision (1σ @ 20 m)
    2 cm¹
    Angular Precision
    < 0.1º
    Beam Divergence
    0.28° (Vertical) × 0.03° (Horizontal)
    Point Rate
    100,000 points/s (Mid-40)
    300,000 points/s (Mid-100)
    FOV Coverage
    20% @ 0.1 s, 68% @0.5 s, 93% @ 1 s ²
    False Alarm Rate (@ 100 klx) ³
    < 0.01%
    Operating Temperature
    -4˚F to 149˚F (-20˚C to 65˚C)
    IP Rating
    IP67⁴
    Power
    10 W typical⁵ (Mid-40)
    30 W typical⁵ (Mid-100)
    Voltage
    10 ~ 16 V DC(Typical 12 V DC)
    Interface
    Ethernet
    Data synchronization:
    IEEE 1588-2008 (PTPv2), PPS (Pulse Per Second)
    Dimensions
    88×69×76 mm (Mid-40)
    142×70×230 mm (Mid-100)
    Weight
    Approx. 760 g (Mid-40)
    Approx. 2200 g (Mid-100)
    Data Latency
    2ms
    Notes
    1. Measured in an environment of 25℃ with a target (80% reflectivity) 20 meters away. The result may vary under different test conditions.
    2. For more information, refer to the user manual.
    3. The proportion of false alarms generated by ambient stray light in daylight conditions of 100 klx.
    4. Operating fan is rated IP55.
    5. Starting power, especially at low temperature, might be significantly larger than the typical power. Please refer to user manuals for detailed information.